Moisture in Steam

Hawkins' Electrical Dictionary · 1915 · p. 3
—lIt is important to ascertain the quality of the steam in making boiler and engine tests. When the condenser test cannot be made, the steam may be tested by a calorimeter as follows: A perforated 4 inch pipe is inserted into the main steam pipe near the boiler. Steam is taken through this pipe and led through a hose thoroughly felted, to a barrel holding 400 lbs. of water, set upon a platform scale, and provided with a valve for allowing the water to flow to waste, and with a small propeller for stirring the water. After weighing barrel and water, and noting open a of the latter, steam is turned on and the hose suddenly thrust into the water, and propeller operated until temperature is increased to, say, 110°. The hose is quickly withdrawn, temperature noted and weight again taken. The moisture in the steam may then be calculated as follows: Q= gr1 [E W umera]; in which Q=quality of the steam, saturated steam being ity. H=total heat of one lb. of steam at observed pre ure. T= total heat of one lb. of water at temperature of steam of the observed pre ure. A=total heat of one lb. of condensing water, original. r Eaa heat of one lb. of condensing water, nal. W=Weight of condensing water, corrected for apparatus. w=weight of steam condensed. Percentage of moisture=1-Q.
Readham'da tam maddeyi gor →